Benchtop Environmental Chamber

The TestEQ benchtop environmental chamber is a compact chamber for exposing small products, components, materials and assemblies to controlled temperature and humidity conditions. It is intended for component-level testing where laboratory space and test volume are limited.

Applications

  • Component reliability and early-stage product validation
  • Electronics, PCBs, sensors and small assemblies
  • Damp heat and accelerated aging
  • Material conditioning and environmental durability
  • Quality-control and university research laboratories

Configuration and features

  • Compact 22.5 L and 64 L configurations for benches and small work areas.
  • Temperature range -65 °C to +150 °C.
  • Temperature fluctuation ≤ ±0.5 °C; temperature deviation ≤ ±2.0 °C.
  • Humidity range 5 % to 98 % RH; humidity deviation ±3.0 % RH (above 75 % RH).
  • Programmable multi-step temperature and humidity profiles for repeatable test cycles.
  • Noise level ≤ 68 dB.
  • Configurable options include access ports, inner doors, data recording, water purification, customised sample fixtures and country-specific electrical configuration.

Specifications

Model range (MITH series)

ParameterMITH-270A20MITH-270A40MITH-270A60MITH-640A20MITH-640A40MITH-640A60
Capacity0.0225 m³0.0225 m³0.0225 m³0.064 m³0.064 m³0.064 m³
Internal dimension W×H×D300×300×250 mm300×300×250 mm300×300×250 mm400×400×400 mm400×400×400 mm400×400×400 mm
External dimension W×H×D550×850×900 mm550×850×900 mm550×850×900 mm1300×1150×1000 mm1300×1150×1000 mm1300×1150×1000 mm
Temperature range-20 °C to +100 °C-40 °C to +100 °C-60 °C to +100 °C-20 °C to +100 °C-40 °C to +100 °C-65 °C to +100 °C

Common specifications

ParameterValue
Capacity22.5 L and 64 L
Temperature range-65 °C to +150 °C
Temperature fluctuation≤ ±0.5 °C
Temperature deviation≤ ±2.0 °C
Humidity range20 % to 98 % RH (5 % RH optional)
Humidity deviation±3.0 % RH (above 75 % RH); ±5.0 % RH (≤ 75 % RH)
Noise≤ 68 dB
Optional accessoriesInner door with operation hole, recorder, water purifier, etc
PowerAC 220 V, 1-phase, 3-line, 50/60 Hz

Standards

Benchtop chambers can be used for test programs based on IEC 60068, MIL-STD-810, ISO 16750, ASTM D4332 and applicable ISTA test procedures.

For components that require larger volumes or higher throughput, a floor-standing or walk-in chamber may be more suitable. To confirm a configuration, contact us with the specimen size and required conditions.

Tell us the test standard and the specimen

Send the standard, the specimen size and heat load, the temperature or pressure range. Our engineers will come back with a chamber configuration.