ESS Test Chamber — Environmental Stress Screening

The TestEQ ESS test chamber applies controlled temperature cycling and rapid temperature transitions to production units in order to expose latent manufacturing defects before shipment. Environmental stress screening complements functional test by stressing every unit, or a defined sample, with a repeatable profile. The temperature chamber model series is the ET series, and rapid-change ESS configurations use the EATH series.

Applications

  • Production screening for latent manufacturing defects
  • Manufacturing quality control and early-failure screening
  • Electronics, PCB assemblies and modules
  • Automotive and EV electronics
  • Components requiring a defined screening profile

Configuration and features

  • Temperature range -70 °C to +180 °C.
  • Temperature change rate 5 °C/min to 25 °C/min (optional); common rates are 5, 10, 15 and 20 °C/min.
  • Temperature fluctuation ≤ ±0.5 °C; temperature deviation ≤ ±2.0 °C; temperature uniformity ≤ 2.0 °C.
  • Airflow 198 / 260 / 472 L/Sec (Cold Fusion) depending on model.
  • Humidity and other environmental stresses can be combined depending on the screening program.
  • Popular screening ranges: -40 °C to +85 °C; -45 °C to +85 °C (+125 °C); -55 °C to +85 °C (+125 °C) for military-level requirements.
  • Capacity 100 L to 12,000 L.
  • Pump water supply; water tank capacity 25 L or 40 L.
  • Patent No.: CN201920954255.X.

Specifications

Model range (EATH series)

ModelEATH225-40EATH225-70EATH408-40EATH408-70EATH1000-40EATH1000-70
Capacity (m³)0.2450.2450.4080.4081.01.0
Interior W×H×D (mm)700×700×500700×700×500700×800×730700×800×7301000×1000×10001000×1000×1000
Exterior W×H×D (mm)900×1680×1300900×1680×1300900×1780×1500900×1780×15001200×1980×17001200×1980×1700
Temperature range-40 to +180 °C-70 to +180 °C-40 to +180 °C-70 to +180 °C-40 to +180 °C-70 to +180 °C
Airflow198 L/Sec198 L/Sec260 L/Sec260 L/Sec472 L/Sec472 L/Sec
Window W×H (mm)300×360300×360300×360300×360380×520380×520
Noise heating / cooling (dB)49 / 6549 / 6849 / 6549 / 6849 / 6749 / 68

Common specifications

ParameterValue
Temperature fluctuation≤ ±0.5 °C
Temperature deviation≤ ±2.0 °C
Temperature uniformity≤ 2.0 °C
Temperature change rate5–25 °C/min (optional); common rates 5, 10, 15 and 20 °C/min
Temperature change range-40 to +85 °C (popular); -45 to +85 °C (+125 °C); -55 to +85 °C (+125 °C, military level)
Humidity range (%RH)10–98 %RH
Humidity uniformity±1.0 %RH
Relative humidity deviation≤ +2.0 to −3 %RH (>75 %RH); ≤ ±5.0 %RH (≤75 %RH)
Water supplypump supply
Water tank capacity25 L / 40 L
PowerAC380V, 3 phase 5 lines, 50/60 Hz
Capacity100 to 12,000 L
Patent No.CN201920954255.X

The humidity indicator applies to humidity-configured chambers. Ramp-rate performance depends on chamber size, test range, specimen mass, fixture design and test conditions.

Standards

ESS programs are commonly aligned with JESD22, IEC 60068, MIL-STD-810 and MIL-STD-883, and with thermal-cycling requirements such as JESD22-A104, IEC 60068-2-14, AEC-Q100 and ISO 16750.

To define a screening profile and throughput, contact us with the unit, defect history and required stress level. Related: HALT / HASS Test Chamber , Rapid Temperature Change Chamber .

Tell us the test standard and the specimen

Send the standard, the specimen size and heat load, the temperature or pressure range. Our engineers will come back with a chamber configuration.