<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Environmental Test Chambers and Reliability Test Systems on TestEQ — Environmental Test Chamber Manufacturer</title><link>https://www.testeqglobal.com/projects/</link><description>Recent content in Environmental Test Chambers and Reliability Test Systems on TestEQ — Environmental Test Chamber Manufacturer</description><generator>Hugo</generator><language>en</language><atom:link href="https://www.testeqglobal.com/projects/index.xml" rel="self" type="application/rss+xml"/><item><title>Altitude (Low-pressure) Test Chamber — EQT Series</title><link>https://www.testeqglobal.com/projects/altitude-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/altitude-test-chamber/</guid><description>&lt;p&gt;The TestEQ EQT-series altitude test chamber reproduces controlled high-altitude environmental conditions for product development, qualification, reliability testing and research. Instead of testing at an actual high-altitude location, the chamber reduces atmospheric pressure to a defined condition in a controlled laboratory. The control parameter is absolute pressure; altitude is used as the equivalent environmental reference.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Aviation and aerospace equipment and instruments&lt;/li&gt;&#10;&lt;li&gt;Electronics and electromechanical components for high-altitude use&lt;/li&gt;&#10;&lt;li&gt;Automotive and EV components for altitude and pressure conditions&lt;/li&gt;&#10;&lt;li&gt;Materials, seals and packaging&lt;/li&gt;&#10;&lt;li&gt;Research and system-level test articles&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Wide altitude simulation range: 0 to 50,000 ft (0–15,000 m).&lt;/li&gt;&#10;&lt;li&gt;Precise pressure regulation: ±0.1 kPa.&lt;/li&gt;&#10;&lt;li&gt;Combined temperature and humidity control can be configured with pressure simulation.&lt;/li&gt;&#10;&lt;li&gt;Pressure control tolerance ≤ ±5 kPa across 40 kPa to 4 kPa, and ≤ ±0.1 kPa across 4 kPa to 1 kPa.&lt;/li&gt;&#10;&lt;li&gt;Fast depressurisation: 75.2 kPa to 18.8 kPa within ≤ 15 s (optional), and within ≤ 0.1 s (optional) for specific configurations.&lt;/li&gt;&#10;&lt;li&gt;Humidity range 10 % to 98 % RH; humidity deviation ≤ ±2.0 to 3.0 % RH (above 75 % RH) and ≤ ±5.0 % RH (≤ 75 % RH).&lt;/li&gt;&#10;&lt;li&gt;For large products, assemblies and system-level test articles, customised and walk-in altitude chambers can be developed around the required test volume, pressure range, temperature conditions and laboratory workflow.&lt;/li&gt;&#10;&lt;li&gt;Patent number CN202310792763.3.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range"&gt;Model range&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQT125-70W&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQT512-70W&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQT800-70W&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQT1000-70W&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQT2160-70W&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQT9.0-70W&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal capacity (m³)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.125&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.512&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.8&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2.16&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;8.9&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal dimension W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;500×500×500&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;800×800×800&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×800&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×1000&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1800×1000×1200&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1730×1980×2600&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;External dimension W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;900×1680×1750&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1200×1880×2050&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1400×2080×2050&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1400×2180×2250&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2200×2180×2570&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2130×2440×4673&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Heating rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Cooling rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;3 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;3 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1–3 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1–3 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1–3 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1–3 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Approximate weight (kg)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;850&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1500&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1900&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2000&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;3500&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;9520&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Altitude simulation range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0 to 50,000 ft (0–15,000 m)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Normal pressure to 0.5 kPa (500 Pa)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure regulation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±0.1 kPa&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure error (normal → 40 kPa)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±2 kPa&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure error (40 → 4 kPa)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±5 kPa&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure error (4 → 1 kPa)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.1 kPa&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Depressurisation time&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Site level to 15,250 m in 10 min; to 22,860 m in 20 min; to 30,500 m in 30 min&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Rapid decompression (75.2 → 18.8 kPa)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 15 s (optional)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Explosive decompression (75.2 → 18.8 kPa)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 0.1 s (optional)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;−70 °C to +180 °C (+200 °C optional)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature fluctuation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.5 °C (normal pressure, no load, constant state)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±2.0 °C (normal pressure, no load, constant state)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;10 % to 98 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±1.0 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±2.0 to 3.0 % RH (&amp;gt; 75 % RH); ≤ ±5.0 % RH (≤ 75 % RH)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Noise&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 68 dB&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;Notes: external dimensions and noise level exclude the vacuum pump unit (operating temperature range −40 °C to +85 °C). Optional low-pressure and low-temperature humidity control equipment is available. Other dimensions are customisable; detailed parameters require contact with the sales team. Actual performance depends on chamber size, test load, heat generation, required pressure and customer test profile.&lt;/p&gt;</description></item><item><title>Battery Test Chamber for Lithium-Ion, EV Battery and ESS Testing</title><link>https://www.testeqglobal.com/projects/battery-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/battery-test-chamber/</guid><description>&lt;p&gt;The TestEQ battery test chamber provides controlled temperature and optional humidity environments for lithium-ion cells, modules and battery packs. It supports the environmental parts of battery qualification — thermal cycling, temperature exposure and combined climate testing — and can be paired with TestEQ altitude, thermal shock and vibration systems to cover a full UN38.3 test program.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Electric vehicle battery packs&lt;/li&gt;&#10;&lt;li&gt;Energy storage systems (ESS)&lt;/li&gt;&#10;&lt;li&gt;Consumer and industrial lithium battery products&lt;/li&gt;&#10;&lt;li&gt;Battery cells, modules and battery packs&lt;/li&gt;&#10;&lt;li&gt;Third-party and OEM reliability laboratories&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Wide temperature testing range for battery environmental simulation.&lt;/li&gt;&#10;&lt;li&gt;Optional humidity control for combined climate testing.&lt;/li&gt;&#10;&lt;li&gt;Optimised airflow for uniform thermal distribution.&lt;/li&gt;&#10;&lt;li&gt;Reinforced explosion-proof safety design available.&lt;/li&gt;&#10;&lt;li&gt;Supports cell, module and battery pack testing.&lt;/li&gt;&#10;&lt;li&gt;Integrated safety alarms and emergency shutdown systems.&lt;/li&gt;&#10;&lt;li&gt;Custom chamber size and fixture design available.&lt;/li&gt;&#10;&lt;li&gt;Thermal chambers configured for ±0.5 °C temperature accuracy for thermal cycling tests.&lt;/li&gt;&#10;&lt;li&gt;Programmable test profiles, remote monitoring and data logging and reporting for certification documentation.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Test specimens&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;cells, modules and battery packs&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature accuracy&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±0.5 °C (thermal chamber configuration)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity control&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;optional, for combined climate testing&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Low-pressure testing&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;altitude simulation chamber for UN38.3 T1&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Combined testing&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;configurable with altitude, thermal shock and vibration systems&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Safety&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;reinforced explosion-proof design available; integrated alarms and emergency shutdown&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Documentation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;programmable profiles with data logging and reporting&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;The required chamber configuration depends on the battery type, test method and qualification program; chamber size and fixtures are customised accordingly.&lt;/p&gt;</description></item><item><title>Benchtop Environmental Chamber</title><link>https://www.testeqglobal.com/projects/benchtop-environmental-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/benchtop-environmental-chamber/</guid><description>&lt;p&gt;The TestEQ benchtop environmental chamber is a compact chamber for exposing small products, components, materials and assemblies to controlled temperature and humidity conditions. It is intended for component-level testing where laboratory space and test volume are limited.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Component reliability and early-stage product validation&lt;/li&gt;&#10;&lt;li&gt;Electronics, PCBs, sensors and small assemblies&lt;/li&gt;&#10;&lt;li&gt;Damp heat and accelerated aging&lt;/li&gt;&#10;&lt;li&gt;Material conditioning and environmental durability&lt;/li&gt;&#10;&lt;li&gt;Quality-control and university research laboratories&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Compact 22.5 L and 64 L configurations for benches and small work areas.&lt;/li&gt;&#10;&lt;li&gt;Temperature range -65 °C to +150 °C.&lt;/li&gt;&#10;&lt;li&gt;Temperature fluctuation ≤ ±0.5 °C; temperature deviation ≤ ±2.0 °C.&lt;/li&gt;&#10;&lt;li&gt;Humidity range 5 % to 98 % RH; humidity deviation ±3.0 % RH (above 75 % RH).&lt;/li&gt;&#10;&lt;li&gt;Programmable multi-step temperature and humidity profiles for repeatable test cycles.&lt;/li&gt;&#10;&lt;li&gt;Noise level ≤ 68 dB.&lt;/li&gt;&#10;&lt;li&gt;Configurable options include access ports, inner doors, data recording, water purification, customised sample fixtures and country-specific electrical configuration.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range-mith-series"&gt;Model range (MITH series)&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MITH-270A20&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MITH-270A40&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MITH-270A60&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MITH-640A20&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MITH-640A40&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MITH-640A60&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.0225 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.0225 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.0225 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.064 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.064 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.064 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal dimension W×H×D&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×300×250 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×300×250 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×300×250 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;400×400×400 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;400×400×400 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;400×400×400 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;External dimension W×H×D&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;550×850×900 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;550×850×900 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;550×850×900 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1300×1150×1000 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1300×1150×1000 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1300×1150×1000 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-20 °C to +100 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-40 °C to +100 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-60 °C to +100 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-20 °C to +100 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-40 °C to +100 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-65 °C to +100 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;22.5 L and 64 L&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-65 °C to +150 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature fluctuation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.5 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;20 % to 98 % RH (5 % RH optional)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±3.0 % RH (above 75 % RH); ±5.0 % RH (≤ 75 % RH)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Noise&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 68 dB&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Optional accessories&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Inner door with operation hole, recorder, water purifier, etc&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;AC 220 V, 1-phase, 3-line, 50/60 Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h2 id="standards"&gt;Standards&lt;/h2&gt;&#10;&lt;p&gt;Benchtop chambers can be used for test programs based on IEC 60068, MIL-STD-810, ISO 16750, ASTM D4332 and applicable ISTA test procedures.&lt;/p&gt;</description></item><item><title>Composite Salt Spray Test Chamber — SSTC / W-STH Series</title><link>https://www.testeqglobal.com/projects/salt-spray-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/salt-spray-test-chamber/</guid><description>&lt;p&gt;The TestEQ composite salt spray test chamber runs salt spray, high-humidity, drying and optional temperature phases in one programmable cabinet, so corrosion is driven through realistic wet-dry and salt-fog cycles rather than continuous spray alone. Cabinet models cover small to medium samples; walk-in models take oversized assemblies such as vehicle parts and battery enclosures.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Automotive parts, fasteners, chassis components and coatings&lt;/li&gt;&#10;&lt;li&gt;EV battery enclosures, connectors and terminals&lt;/li&gt;&#10;&lt;li&gt;Aerospace structures and surface treatments&lt;/li&gt;&#10;&lt;li&gt;Marine equipment and offshore structures&lt;/li&gt;&#10;&lt;li&gt;Paints, coatings and metal finishing&lt;/li&gt;&#10;&lt;li&gt;Electronics, connectors and plating&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Cyclic corrosion: salt spray, humidity, drying and optional temperature variation in programmed multi-stage profiles.&lt;/li&gt;&#10;&lt;li&gt;Test modes ACSS, SOAK, DRYAIR, HUMI and ROOMAIR on walk-in models.&lt;/li&gt;&#10;&lt;li&gt;Continuous or programmable spray.&lt;/li&gt;&#10;&lt;li&gt;Uniform salt fog distribution with a precision nozzle system.&lt;/li&gt;&#10;&lt;li&gt;Corrosion-resistant structure for long-duration testing.&lt;/li&gt;&#10;&lt;li&gt;Saline concentration 5 % NaCl, or 0.26 g CuCl₂·2H₂O added per litre of 5 % NaCl for CASS.&lt;/li&gt;&#10;&lt;li&gt;Compressed air pressure 1.0 to 6.0 kgf.&lt;/li&gt;&#10;&lt;li&gt;Spray volume 1.0–2.0 ml/80 cm²/h, averaged over at least 16 hours of working time.&lt;/li&gt;&#10;&lt;li&gt;Optional SO₂ corrosion module, temperature cycling integration, remote monitoring and data logging, and acid-resistant materials for CASS.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="cabinet-model-range"&gt;Cabinet model range&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SSTC-60&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SSTC-90&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SSTC-120&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SSTC-160&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SSTC-200&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity (m³)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.11&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.27&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.50&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.80&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.50&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal dimension W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;600×400×450&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;900×500×600&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1200×500×800&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1600×500×800&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2000×500×800&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;External dimension W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1100×960×760&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1400×1200×900&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1900×1300×1400&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2150×1350×1400&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2700×1500×1700&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Saline capacity (L)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;25&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;40&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;40&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;40&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Weight (kg)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;65&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;80&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;120&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;160&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;200&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="walk-in-model-range"&gt;Walk-in model range&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;W-STH-4000&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;W-STH-5000&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;W-STH-8000&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;W-STH-10000&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;W-STH-12000&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity (m³)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;3.78&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;5&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;8&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;11.5&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;12&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal dimension W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1500×1800×1400&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1700×1800×1600&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2000×2000×2000&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2600×2000×2200&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2000×2000×3000&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;External dimension W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1600×2850×2380&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1800×2850×2580&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2200×3050×2980&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2800×3050×3180&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2200×3050×4980&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Lab temperature&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;NSS/ACSS 35 ± 1 °C; CASS 50 ± 1 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure bucket temperature&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;NSS/ACSS 47 ± 1 °C; CASS 63 ± 1 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Saline concentration&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;5 % NaCl, or 0.26 g CuCl₂·2H₂O per litre of 5 % NaCl&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Compressed air pressure&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0–6.0 kgf&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Spray volume&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0–2.0 ml/80 cm²/h (at least 16 h working time, average value)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Spray form&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;continuous or programmable&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Walk-in test modes&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ACSS, SOAK, DRYAIR, HUMI, ROOMAIR&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Walk-in temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;A: RT (+15 °C) to +85 °C; B: -10 °C to +85 °C; C: -20 °C to +85 °C; D: -40 °C to +85 °C; E: -55 °C to +85 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Walk-in humidity range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;20 % to 98 % RH; 15 % to 95 % RH with dehumidifier or dryer&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature rising/falling rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;rising approx. 0.1–3.0 °C/min; falling approx. 0.3–1.0 °C/min (3–10 °C/min whole-course average, optional)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Analytic accuracy&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.1 °C; 0.1 % RH; distribution uniformity ±2.0 °C, ±5 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Control accuracy&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±0.5 °C; ±2.5 °C; 2 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;AC 220 V, 1 phase 3 lines, 50/60 Hz; AC 380 V, 3 phase 5 lines, 50/60 Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;Chamber dimensions and special functions are customisable on request; detailed parameters and configurations are available from the sales team.&lt;/p&gt;</description></item><item><title>Custom Non-standard Test Chamber</title><link>https://www.testeqglobal.com/projects/custom-environmental-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/custom-environmental-chamber/</guid><description>&lt;p&gt;Where a standard chamber does not match the test item, the test conditions or the laboratory layout, TestEQ designs and manufactures a non-standard test chamber to the customer&amp;rsquo;s special requirements. Custom projects are developed from the required test conditions rather than from a fixed catalogue model.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Test items outside standard chamber dimensions or weight&lt;/li&gt;&#10;&lt;li&gt;Combined or unusual test conditions (temperature, humidity, altitude, vacuum, vibration)&lt;/li&gt;&#10;&lt;li&gt;System-level test articles that must be operated while under test&lt;/li&gt;&#10;&lt;li&gt;Production or laboratory lines with specific access and handling requirements&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="what-can-be-customised"&gt;What can be customised&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Chamber size, internal dimensions and access (doors, ports, viewing windows)&lt;/li&gt;&#10;&lt;li&gt;Temperature and humidity range, and temperature change rate&lt;/li&gt;&#10;&lt;li&gt;Combined functions such as temperature, humidity, altitude, vacuum or vibration&lt;/li&gt;&#10;&lt;li&gt;Control system, data recording, communication and monitoring&lt;/li&gt;&#10;&lt;li&gt;Refrigeration and air-circulation design for the required load and ramp rate&lt;/li&gt;&#10;&lt;li&gt;Mechanical handling, fixturing and integration with customer equipment&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="development-approach"&gt;Development approach&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Requirements are defined from the test item, test standard and required conditions.&lt;/li&gt;&#10;&lt;li&gt;The thermal, humidity, vacuum or vibration systems are configured together with the structure.&lt;/li&gt;&#10;&lt;li&gt;Where a standard model already matches, a standard or walk-in model is selected instead of a custom build.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="standards"&gt;Standards&lt;/h2&gt;&#10;&lt;p&gt;Custom chambers are designed with reference to the applicable test standards for the application, including GB, GJB, IEC, ASTM and UL. TestEQ operates an ISO 9001 quality management system.&lt;/p&gt;</description></item><item><title>ESS Test Chamber — Environmental Stress Screening</title><link>https://www.testeqglobal.com/projects/ess-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/ess-test-chamber/</guid><description>&lt;p&gt;The TestEQ ESS test chamber applies controlled temperature cycling and rapid temperature transitions to production units in order to expose latent manufacturing defects before shipment. Environmental stress screening complements functional test by stressing every unit, or a defined sample, with a repeatable profile. The temperature chamber model series is the ET series, and rapid-change ESS configurations use the EATH series.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Production screening for latent manufacturing defects&lt;/li&gt;&#10;&lt;li&gt;Manufacturing quality control and early-failure screening&lt;/li&gt;&#10;&lt;li&gt;Electronics, PCB assemblies and modules&lt;/li&gt;&#10;&lt;li&gt;Automotive and EV electronics&lt;/li&gt;&#10;&lt;li&gt;Components requiring a defined screening profile&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Temperature range -70 °C to +180 °C.&lt;/li&gt;&#10;&lt;li&gt;Temperature change rate 5 °C/min to 25 °C/min (optional); common rates are 5, 10, 15 and 20 °C/min.&lt;/li&gt;&#10;&lt;li&gt;Temperature fluctuation ≤ ±0.5 °C; temperature deviation ≤ ±2.0 °C; temperature uniformity ≤ 2.0 °C.&lt;/li&gt;&#10;&lt;li&gt;Airflow 198 / 260 / 472 L/Sec (Cold Fusion) depending on model.&lt;/li&gt;&#10;&lt;li&gt;Humidity and other environmental stresses can be combined depending on the screening program.&lt;/li&gt;&#10;&lt;li&gt;Popular screening ranges: -40 °C to +85 °C; -45 °C to +85 °C (+125 °C); -55 °C to +85 °C (+125 °C) for military-level requirements.&lt;/li&gt;&#10;&lt;li&gt;Capacity 100 L to 12,000 L.&lt;/li&gt;&#10;&lt;li&gt;Pump water supply; water tank capacity 25 L or 40 L.&lt;/li&gt;&#10;&lt;li&gt;Patent No.: CN201920954255.X.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range-eath-series"&gt;Model range (EATH series)&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Model&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EATH225-40&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EATH225-70&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EATH408-40&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EATH408-70&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EATH1000-40&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EATH1000-70&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity (m³)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.245&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.245&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.408&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.408&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Interior W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;700×700×500&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;700×700×500&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;700×800×730&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;700×800×730&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×1000&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×1000&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Exterior W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;900×1680×1300&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;900×1680×1300&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;900×1780×1500&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;900×1780×1500&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1200×1980×1700&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1200×1980×1700&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-40 to +180 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-70 to +180 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-40 to +180 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-70 to +180 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-40 to +180 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-70 to +180 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Airflow&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;198 L/Sec&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;198 L/Sec&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;260 L/Sec&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;260 L/Sec&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;472 L/Sec&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;472 L/Sec&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Window W×H (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×360&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×360&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×360&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×360&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;380×520&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;380×520&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Noise heating / cooling (dB)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;49 / 65&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;49 / 68&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;49 / 65&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;49 / 68&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;49 / 67&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;49 / 68&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature fluctuation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.5 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature change rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;5–25 °C/min (optional); common rates 5, 10, 15 and 20 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature change range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-40 to +85 °C (popular); -45 to +85 °C (+125 °C); -55 to +85 °C (+125 °C, military level)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity range (%RH)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;10–98 %RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±1.0 %RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Relative humidity deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ +2.0 to −3 %RH (&amp;gt;75 %RH); ≤ ±5.0 %RH (≤75 %RH)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Water supply&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;pump supply&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Water tank capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;25 L / 40 L&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;AC380V, 3 phase 5 lines, 50/60 Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;100 to 12,000 L&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Patent No.&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;CN201920954255.X&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;The humidity indicator applies to humidity-configured chambers. Ramp-rate performance depends on chamber size, test range, specimen mass, fixture design and test conditions.&lt;/p&gt;</description></item><item><title>Explosive Atmosphere Test Chamber for Fuel Vapor and Explosion Hazard Testing</title><link>https://www.testeqglobal.com/projects/explosive-atmosphere-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/explosive-atmosphere-test-chamber/</guid><description>&lt;p&gt;The TestEQ explosive atmosphere test chamber reproduces an explosive gas environment inside a closed cabinet so that equipment can be checked for ignition and explosion hazard. It is used to qualify components and enclosures that may operate where flammable gas or vapor is present, following MIL-STD-810H Method 511, IEC 60079, ATEX and customer-specific standards.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Components and enclosures installed in fuel-handling, petrochemical and refinery areas&lt;/li&gt;&#10;&lt;li&gt;Electrical and electronic assemblies intended for hazardous locations&lt;/li&gt;&#10;&lt;li&gt;Aerospace, defence and avionics equipment exposed to fuel vapor&lt;/li&gt;&#10;&lt;li&gt;Sensors, connectors and switches used near flammable gas&lt;/li&gt;&#10;&lt;li&gt;Industrial instrumentation and control systems in Zone-rated environments&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Simulates gasoline vapor, hydrogen, methane, propane and other explosive gas environments.&lt;/li&gt;&#10;&lt;li&gt;Gas concentration control and pressure monitoring integrated into the test cycle.&lt;/li&gt;&#10;&lt;li&gt;Intelligent safety protection for reliable operation during explosive atmosphere testing.&lt;/li&gt;&#10;&lt;li&gt;Available in laboratory, industrial and fully customized chamber sizes.&lt;/li&gt;&#10;&lt;li&gt;PLC touchscreen controller with automatic data logging, alarm management and test report generation.&lt;/li&gt;&#10;&lt;li&gt;Backed by TestEQ&amp;rsquo;s engineering team, offering customized solutions, factory-direct manufacturing and worldwide technical support.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="safety"&gt;Safety&lt;/h2&gt;&#10;&lt;p&gt;Explosive atmosphere testing puts a flammable gas mixture inside the chamber, so safety is built into the working cycle rather than added on top. Gas concentration control and pressure monitoring run alongside an intelligent safety protection layer, and the PLC controller manages alarm management and sequencing so a run can be stopped and vented when a condition moves outside the set window. The chamber is configured for the gas medium and concentration in use, and testing follows the standard or customer procedure that applies to the specimen.&lt;/p&gt;</description></item><item><title>Four Combined Environmental Test Chamber — EQTH Series</title><link>https://www.testeqglobal.com/projects/four-combined-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/four-combined-test-chamber/</guid><description>&lt;p&gt;The TestEQ four combined environmental test chamber integrates temperature, humidity, vibration and altitude simulation into one coordinated test platform. It is built for products that must operate or survive under combined climatic, mechanical and reduced-pressure conditions, and it is configured around the actual qualification program rather than a single nominal chamber volume.&lt;/p&gt;&#10;&lt;h2 id="what-a-four-combined-chamber-is"&gt;What a four combined chamber is&lt;/h2&gt;&#10;&lt;p&gt;A four combined environmental test chamber controls temperature and humidity while applying mechanical vibration and altitude or low-pressure conditions. The four environmental factors are programmed according to the required qualification sequence rather than run as four separate tests. The system may include temperature conditioning, humidity control, low-pressure / altitude simulation, electrodynamic vibration, customized specimen fixtures, environmental monitoring and programmable test control.&lt;/p&gt;</description></item><item><title>HALT / HASS Test Chamber — ETH² Series</title><link>https://www.testeqglobal.com/projects/halt-hass-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/halt-hass-test-chamber/</guid><description>&lt;p&gt;The TestEQ ETH²-series HALT / HASS test chamber is an integrated environmental and multi-axis vibration test system. It accelerates failure discovery during product development and controlled production screening by combining rapid temperature transitions with multi-axis repetitive shock vibration, helping reliability engineers identify design weaknesses, determine operating and destruct limits, and evaluate robustness under combined stress.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Design-margin discovery (HALT) and production screening (HASS)&lt;/li&gt;&#10;&lt;li&gt;Electronics, PCB assemblies and interconnects&lt;/li&gt;&#10;&lt;li&gt;Automotive and EV power electronics&lt;/li&gt;&#10;&lt;li&gt;Aerospace, defense and communication equipment&lt;/li&gt;&#10;&lt;li&gt;Components and modules where latent defects must be exposed early&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Capacity 215 to 1100 L (customizable).&lt;/li&gt;&#10;&lt;li&gt;Temperature range -100 °C to +200 °C.&lt;/li&gt;&#10;&lt;li&gt;Rapid temperature transition: up to 100 °C/min (standard support from 30 °C/min to 70 °C/min as an option).&lt;/li&gt;&#10;&lt;li&gt;Cooling method: liquid nitrogen (LN₂).&lt;/li&gt;&#10;&lt;li&gt;Vibration system: 6-DOF pneumatic repetitive shock.&lt;/li&gt;&#10;&lt;li&gt;Vibration frequency range 5 to 10,000 Hz.&lt;/li&gt;&#10;&lt;li&gt;Vibration acceleration ≥ 100 g under no-load condition.&lt;/li&gt;&#10;&lt;li&gt;Vibration range 5 to 100 GRMS; vibration overshoot ≤ 2 GRMS.&lt;/li&gt;&#10;&lt;li&gt;Consistency ≤ 20 %.&lt;/li&gt;&#10;&lt;li&gt;Multi-axis vibration is integrated with the thermal system; the DUT can be monitored for functional degradation, intermittent failures and structural weaknesses.&lt;/li&gt;&#10;&lt;li&gt;Extended vibration range available up to 70 Grms.&lt;/li&gt;&#10;&lt;li&gt;Power supply AC 380 V, 3-phase, 5-wire, 50/60 Hz.&lt;/li&gt;&#10;&lt;li&gt;Patent number CN201520670413.0.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range-eth-series"&gt;Model range (ETH² series)&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;ETH²-460&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;ETH²-610&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;ETH²-762&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;ETH²-910&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;ETH²-1213&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.5 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2.0 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2.5 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;3.0 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;4.0 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;External dimension W×H×D&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1570×2030×910 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1330×1300×2370 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1570×2030×1060 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1730×2185×1214 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1886×2440×1370 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Table dimension&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;460×460 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;610×610 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;762×762 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;910×910 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1213×1213 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Max. load&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;70 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;90 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;200 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;250 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;317 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Actuators&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;3 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;4 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;6 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;9 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;13 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Compressed air consumption (at 7 bar)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;400 L/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;400 L/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;990 L/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1130 L/min&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1950 L/min&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Windows&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1 pc&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1 pc&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Viewing window dimension W×D&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×300 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×300 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;300×360 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;380×480 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;380×520 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Doors&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1 pc&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1 pc&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2 pcs&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;27 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;32 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;48 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;64 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;83 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Current&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;50 A&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;50 A&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;86 A&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;150 A&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;175 A&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Weight&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;410 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;420 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;860 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1133 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1814 kg&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-100 °C to +200 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature change rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;up to 100 °C/min (30–70 °C/min standard option)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Cooling method&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Liquid nitrogen (LN₂)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vibration system&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;6-DOF pneumatic repetitive shock&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vibration acceleration&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≥ 100 g (under no-load condition)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vibration frequency range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;5 to 10,000 Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vibration range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;5 to 100 GRMS&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vibration overshoot&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 2 GRMS&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Extended vibration&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;up to 70 Grms&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Liquid nitrogen consumption&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;25 to 60 L/min (liquid nitrogen pressure at 2.8–3.5 bar)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Consistency&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 20 %&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vibration monitoring&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;two vibration channels for real-time monitoring of product vibration and acceleration response spectrum analysis&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power supply&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;AC 380 V, 3-phase, 5-line, 50/60 Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;Model designations include the ETH² series (for example ETH²-460, ETH²-610, ETH²-762, ETH²-910 and ETH²-1213). Temperature ramp rate and vibration performance should be evaluated under the intended DUT load and fixture configuration; unloaded maximum specifications may not represent actual test performance.&lt;/p&gt;</description></item><item><title>HAST / PCT Test Chamber — EQ-PCT Series</title><link>https://www.testeqglobal.com/projects/hast-pct-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/hast-pct-test-chamber/</guid><description>&lt;p&gt;The TestEQ EQ-PCT series covers HAST (Highly Accelerated Stress Test) and PCT (Pressure Cooker Test) in one pressurised chamber. It applies controlled temperature, humidity and pressure to accelerate moisture-related failure mechanisms in non-hermetic electronic components and semiconductor packages, so qualification work that otherwise runs for weeks at 85 °C / 85 % RH can be carried out over a much shorter test period.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Semiconductor packages and ICs&lt;/li&gt;&#10;&lt;li&gt;Non-hermetic electronic components and devices&lt;/li&gt;&#10;&lt;li&gt;PCB assemblies and interconnects&lt;/li&gt;&#10;&lt;li&gt;Automotive electronics and LED devices&lt;/li&gt;&#10;&lt;li&gt;Reliability qualification and failure analysis laboratories&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Steam temperature range +110 °C to +135 °C.&lt;/li&gt;&#10;&lt;li&gt;Humidity: 100 % RH saturated vapour, or 70 % to 100 % RH with adjustable steam humidity.&lt;/li&gt;&#10;&lt;li&gt;Natural convection circulation of water vapour.&lt;/li&gt;&#10;&lt;li&gt;Pressure range 0 to +2 kg/cm², with an operational range of 0 to +3 kg/cm².&lt;/li&gt;&#10;&lt;li&gt;Programmable test duration 0 to 999 hours.&lt;/li&gt;&#10;&lt;li&gt;Pressurisation 0.00 → 2.00 kg/cm² in ≈30 min under no-load conditions.&lt;/li&gt;&#10;&lt;li&gt;Chamber air temperature ambient → 132 °C in ≈30 min.&lt;/li&gt;&#10;&lt;li&gt;Dual-mode water management: automatic or manual replenishment with automatic pressure relief.&lt;/li&gt;&#10;&lt;li&gt;Low-water cutoff protection and overpressure interlock.&lt;/li&gt;&#10;&lt;li&gt;Biased or unbiased HAST configurations with electrical loading, custom fixtures, pressure control and data monitoring.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range"&gt;Model range&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQ-PCT-18&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQ-PCT-48&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQ-PCT-88&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EQ-PCT-199&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal capacity (m³)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.018&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.048&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.088&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.199&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal dimension Ø×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Ø300×250&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Ø450×300&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Ø500×450&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Ø650×600&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;External dimension W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;500×500×700&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;580×850×650&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;800×750×900&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;950×900×1100&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Steam temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;+110 °C to +135 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature fluctuation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.5 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 1.5 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;100 % RH saturated vapour; 70 % to 100 % RH adjustable steam humidity&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±1.5 % RH; ±3.0 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0 to +2 kg/cm² (operational 0 to +3 kg/cm²)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Absolute pressure range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0–3.0 kg/cm²&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Safety pressure capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;4 kg/cm² (1 atmosphere + 3 kg/cm² gauge pressure)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Circulation mechanism&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;natural convection of water vapour&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Test time setting&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0–999 hours, programmable&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressurisation time&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.00 → 2.00 kg/cm² in ≈30 min (no load)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature ramp&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ambient → 132 °C in ≈30 min (chamber air temperature)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;AC 220 V, 1 phase 3 lines, 50/60 Hz; AC 380 V, 3 phase 5 lines, 50/60 Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;Actual test conditions are set according to the applicable standard, the product qualification requirement and the sample configuration. Chamber capacity, fixtures, electrical bias, water management and laboratory integration can be customised.&lt;/p&gt;</description></item><item><title>High and Low Temperature (Humidity) Test Chamber — ETH Series</title><link>https://www.testeqglobal.com/projects/temperature-humidity-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/temperature-humidity-test-chamber/</guid><description>&lt;p&gt;TestEQ ETH-series temperature and humidity test chambers reproduce controlled temperature and humidity conditions for component, assembly and material reliability testing. The series uses application-specific compressors from 0.8 to 8 HP and an optimized air circulation system.&lt;/p&gt;&#10;&lt;p&gt;&lt;img src="https://www.testeqglobal.com/images/projects/temperature-humidity-test-chamber-1.jpg" alt="High and low temperature humidity test chamber"&gt;&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Electronics and PCB assemblies: damp heat, temperature and humidity exposure&lt;/li&gt;&#10;&lt;li&gt;Semiconductor and electronic components&lt;/li&gt;&#10;&lt;li&gt;Automotive and EV components&lt;/li&gt;&#10;&lt;li&gt;Aerospace and defense equipment&lt;/li&gt;&#10;&lt;li&gt;Batteries and power electronics&lt;/li&gt;&#10;&lt;li&gt;Materials, coatings and adhesives&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="chamber-configuration"&gt;Chamber configuration&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Cabinet models from 245 L to 1000 L; large walk-in temperature-humidity systems can be customised up to 4500 m³.&lt;/li&gt;&#10;&lt;li&gt;Temperature range -40 °C to +180 °C or -70 °C to +180 °C, depending on model.&lt;/li&gt;&#10;&lt;li&gt;Humidity range 10 % to 98 % RH (5 % to 98 % RH optional), with pump water supply.&lt;/li&gt;&#10;&lt;li&gt;Constant temperature control ≤ ±0.3 °C for testing stability.&lt;/li&gt;&#10;&lt;li&gt;Dew point temperature range 7 °C to 87 °C; extended dew point conditions -10 °C.&lt;/li&gt;&#10;&lt;li&gt;Application-specific compressors from 0.8 to 8 HP deliver fast product temperature change rates; faster transitions shorten the test cycle.&lt;/li&gt;&#10;&lt;li&gt;Optimised air circulation improves temperature gradient, control precision and reliability.&lt;/li&gt;&#10;&lt;li&gt;7&amp;quot; colour touchscreen controller with program mode (20 programs, up to 50 steps each, up to 20 loops) and fixed-value mode; RS-485 local and remote communication, up to 16 chambers connected with a maximum total cable length of 800 m.&lt;/li&gt;&#10;&lt;li&gt;Over-temperature protection, power-failure protection, upper/lower temperature limits, timed start/stop and self-diagnosis.&lt;/li&gt;&#10;&lt;li&gt;Noise ≤ 68 dB.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;p&gt;&lt;img src="https://www.testeqglobal.com/images/projects/temperature-humidity-test-chamber-3.jpg" alt="Humidity chamber interior"&gt;&lt;/p&gt;</description></item><item><title>High Pressure Test Chamber</title><link>https://www.testeqglobal.com/projects/high-pressure-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/high-pressure-test-chamber/</guid><description>&lt;p&gt;The TestEQ high pressure test chamber is a custom-engineered pressure vessel that reproduces controlled high-pressure conditions for pressure-resistance, leakage, sealing, structural-integrity and reliability testing. Working pressure reaches 50 MPa, and the system can be configured for a gas or a liquid test medium with optional temperature and humidity control.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Aerospace components and pressure-sensitive assemblies&lt;/li&gt;&#10;&lt;li&gt;Automotive and EV battery components&lt;/li&gt;&#10;&lt;li&gt;Valves, seals, joints and fluid-containing parts&lt;/li&gt;&#10;&lt;li&gt;Electronics, energy and industrial equipment&lt;/li&gt;&#10;&lt;li&gt;Pressure resistance, leakage, sealing and structural integrity validation&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Working pressure -0.1 to 50 MPa, configuration dependent.&lt;/li&gt;&#10;&lt;li&gt;Chamber capacity 500 L to 50,000 L.&lt;/li&gt;&#10;&lt;li&gt;Pressure control accuracy ≤ ±0.0002 MPa.&lt;/li&gt;&#10;&lt;li&gt;Gas pressure testing or liquid/hydrostatic pressure testing.&lt;/li&gt;&#10;&lt;li&gt;Optional temperature and humidity control for combined multi-stress testing.&lt;/li&gt;&#10;&lt;li&gt;Pressurisation from ambient pressure to 0.8 MPa in ≤ 30 min; depressurisation from 0.8 MPa to ambient in ≥ 30 min.&lt;/li&gt;&#10;&lt;li&gt;Chamber materials SUS304, SS316L or a customised alloy.&lt;/li&gt;&#10;&lt;li&gt;Sealing systems: magnetic, mechanical, packing or gasket.&lt;/li&gt;&#10;&lt;li&gt;Integrated safety systems: pressure monitoring, over-pressure protection, safety interlocks, controlled pressurisation and depressurisation, emergency shutdown and data recording.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;TestEQ configuration&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Working pressure&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-0.1 to 50 MPa, configuration dependent&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Chamber capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;500–50,000 L&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure accuracy&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.0002 MPa&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure medium&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Gas / liquid&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity control&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;20–80 % RH, optional&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressurisation rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ambient pressure to 0.8 MPa ≤ 30 min&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Depressurisation rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.8 MPa to ambient pressure ≥ 30 min&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Chamber material&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;SUS304 / SS316L / customised alloy&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Sealing system&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;magnetic / mechanical / packing / gasket&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Configuration&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;standard or custom engineered&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;Actual performance depends on the pressure range, chamber size, test medium, temperature requirements and customer test conditions.&lt;/p&gt;</description></item><item><title>Icing Test Chamber — Ice Accretion and Freezing Rain Testing</title><link>https://www.testeqglobal.com/projects/icing-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/icing-test-chamber/</guid><description>&lt;p&gt;The TestEQ icing test chamber grows a controlled layer of ice on a test item and holds it there long enough to run functional checks. Cooling and water-spray sequences are configured around the specimen, so a component, a subassembly or a full vehicle can be frozen, sprayed and tested in the same cabinet. It is used wherever equipment has to keep working after ice has formed on it — airborne equipment qualified against an icing requirement, and automotive or outdoor hardware exposed to freezing rain and road spray.&lt;/p&gt;</description></item><item><title>Mixed Gas Corrosion Test Chamber</title><link>https://www.testeqglobal.com/projects/mixed-gas-corrosion-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/mixed-gas-corrosion-test-chamber/</guid><description>&lt;p&gt;The TestEQ mixed gas corrosion test chamber exposes electronic components, contacts and assemblies to a controlled flowing mixture of corrosive gases, reproducing the corrosive atmospheres that cause contact and interconnection failures in service. The test is intended for the IEC 60068-2-60 flowing mixed gas method.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Electronic components, connectors and contacts&lt;/li&gt;&#10;&lt;li&gt;PCB assemblies, plated through-holes and interconnects&lt;/li&gt;&#10;&lt;li&gt;Equipment used in industrial, automotive and telecommunication environments&lt;/li&gt;&#10;&lt;li&gt;Reliability and qualification testing for corrosion resistance&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Flowing mixed gas method for IEC 60068-2-60 corrosion testing.&lt;/li&gt;&#10;&lt;li&gt;Gas concentration adjustable from 0.1 ppm to 25 ppm (range varies by gas type).&lt;/li&gt;&#10;&lt;li&gt;Controlled gas mixture, temperature and humidity for repeatable exposure conditions.&lt;/li&gt;&#10;&lt;li&gt;Supports simultaneous dosing of up to four gases (H₂S, SO₂, Cl₂ with N₂ carrier gas; NO₂ with synthetic air) for multi-pollutant interaction studies.&lt;/li&gt;&#10;&lt;li&gt;Acrylic (PMMA) viewing window for real-time monitoring of specimens.&lt;/li&gt;&#10;&lt;li&gt;Pressure monitoring system and gas sampling port for operator safety.&lt;/li&gt;&#10;&lt;li&gt;Integrated air exchange module for consistent gas distribution.&lt;/li&gt;&#10;&lt;li&gt;Programmable test profiles for batch or continuous exposure.&lt;/li&gt;&#10;&lt;li&gt;The equipment can be evolved into a sulfur dioxide corrosion test chamber and a hydrogen sulfide corrosion test chamber.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range"&gt;Model range&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MGCC225&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MGCC408&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MGCC512&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;MGCC1000&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.245 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.408 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.512 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal dimension W×H×D&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;700×700×500 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;700×800×730 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;800×800×800 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×1000 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;9.5 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;11.5 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;14.5 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;18.5 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Volume&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;245 L (3.5 ft³) to 1000 L (70.6 ft³) (customizable)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Supported gases&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;H₂S, SO₂, Cl₂, NO₂&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Sulfur dioxide (SO₂) concentration&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;10 ppb to 30 ppm (adjustable)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Hydrogen sulfide (H₂S) concentration&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;5 ppb to 15 ppm (adjustable)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Nitrogen dioxide (NO₂) concentration&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;100 ppb to 500 ppb (adjustable)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Chlorine (Cl₂) concentration&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;5 ppb to 50 ppb (adjustable)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Concentration range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;adjustable from 0.1 ppm to 25 ppm (varies by gas type)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Test duration&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0 to 9999 H, M, S (adjustable)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Air change rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;3 to 10 cycles; general selection 3 / 4 / 5 times (according to actual needs)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range (test)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;+15 °C to +60 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature fluctuation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.5 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;50 % RH to 90 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ (+2, -3) % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 3 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;AC 380 V, 3-phase, 5-line, 50/60 Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;General operating capabilities of the platform include a temperature range of -40 °C to +150 °C, temperature accuracy ±0.5 °C, humidity range 20 % to 98 % RH and humidity accuracy ±2 % RH.&lt;/p&gt;</description></item><item><title>Rapid Decompression and Explosive Decompression Test Chamber</title><link>https://www.testeqglobal.com/projects/rapid-decompression-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/rapid-decompression-test-chamber/</guid><description>&lt;p&gt;The TestEQ rapid decompression test chamber reduces the pressure inside the working volume faster than a normal altitude change, so a test item experiences the pressure-acclimatisation event that follows a loss of cabin pressure at altitude. The chamber is a pressure vessel built for two evacuation rates — rapid decompression and explosive decompression — and is delivered with the temperature, humidity and altitude control of the underlying platform.&lt;/p&gt;&#10;&lt;h2 id="overview"&gt;Overview&lt;/h2&gt;&#10;&lt;p&gt;Aircraft cabins, cargo holds and pressurised containers hold a pressure that differs from the air outside. When that pressure is released suddenly, everything inside is exposed to a step change in pressure over a very short time. Ground tests reproduce this event in two severities:&lt;/p&gt;</description></item><item><title>Rapid Temperature Change Chamber — EATH Series</title><link>https://www.testeqglobal.com/projects/rapid-temperature-change-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/rapid-temperature-change-chamber/</guid><description>&lt;p&gt;The TestEQ EATH-series rapid temperature change chamber applies controlled linear temperature ramps to a product to accelerate thermal fatigue and reveal temperature-related failure mechanisms. It is intended for thermal cycling where transition rate, uniformity and repeatability are critical.&lt;/p&gt;&#10;&lt;p&gt;&lt;img src="https://www.testeqglobal.com/images/projects/rapid-temperature-change-chamber-1.jpg" alt="Rapid temperature change chamber"&gt;&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Semiconductor and IC reliability and thermal cycling&lt;/li&gt;&#10;&lt;li&gt;PCB assemblies, solder joints and interconnects&lt;/li&gt;&#10;&lt;li&gt;Automotive electronics and EV power modules&lt;/li&gt;&#10;&lt;li&gt;Aerospace and communication equipment&lt;/li&gt;&#10;&lt;li&gt;Battery cells and modules&lt;/li&gt;&#10;&lt;li&gt;Materials and coatings&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Temperature range -70 °C to +180 °C (200 °C optional).&lt;/li&gt;&#10;&lt;li&gt;Linear temperature ramp rates from 5 °C/min to 30 °C/min; common rates are 5, 10, 15, 20 and 25 °C/min, with up to 30 °C/min available for selected configurations.&lt;/li&gt;&#10;&lt;li&gt;Popular test range -40 °C to +85 °C.&lt;/li&gt;&#10;&lt;li&gt;Temperature fluctuation ≤ ±0.5 °C; temperature deviation ≤ ±2.0 °C; temperature uniformity ≤ 2.0 °C.&lt;/li&gt;&#10;&lt;li&gt;Temperature uniformity and control stability maintained at high ramp rates.&lt;/li&gt;&#10;&lt;li&gt;Air circulation is designed to keep temperature uniformity and the rate at which the specimen sees the programmed temperature consistent.&lt;/li&gt;&#10;&lt;li&gt;Air-cooled &amp;ldquo;Cold Fusion&amp;rdquo; airflow design.&lt;/li&gt;&#10;&lt;li&gt;Pump water supply; window W×H 380×520 mm.&lt;/li&gt;&#10;&lt;li&gt;PID control with programmable profile and RS-485 communication.&lt;/li&gt;&#10;&lt;li&gt;Options include a high ramp rate upgrade (≥ 30 °C/min).&lt;/li&gt;&#10;&lt;li&gt;Patent No.: CN201920954255.X.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range-eath-series"&gt;Model range (EATH series)&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Models&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Capacity (m³)&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Interior W×H×D (mm)&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;EATH800-40W5 / EATH800-40W10 / EATH800-40W15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.8&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×800&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;EATH800-55W5 / EATH800-55W10 / EATH800-55W15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.8&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×800&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;EATH1000-40W5 / EATH1000-40W10 / EATH1000-40W15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×1000&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;EATH1000-55W5 / EATH1000-55W10 / EATH1000-55W15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×1000&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;The suffix after W indicates the configured ramp rate (W5 = 5 °C/min, W10 = 10 °C/min, W15 = 15 °C/min). Exterior dimensions vary with the accelerated-rate and temperature-range configuration; the source lists exterior W×H×D values of 1200×900×2670, 1200×930×2870, 1200×900×1970 and 1200×1900×2870 mm across the EATH800 / EATH1000 range.&lt;/p&gt;</description></item><item><title>Sand and Dust Test Chamber — SDB / SDJ Series</title><link>https://www.testeqglobal.com/projects/sand-dust-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/sand-dust-test-chamber/</guid><description>&lt;p&gt;The TestEQ sand and dust test chamber reproduces airborne dust, sand particle and dry-climate conditions inside a controlled cabinet. It is used to verify enclosure protection against dust ingress and particle contamination in desert, construction, military and industrial environments, following IEC 60529 IP5X/IP6X, MIL-STD-810H Method 510.7 and ISO 20653.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Automotive components, sensors, ECUs and charging systems&lt;/li&gt;&#10;&lt;li&gt;EV battery components and enclosures&lt;/li&gt;&#10;&lt;li&gt;Aerospace, avionics and outdoor communication equipment&lt;/li&gt;&#10;&lt;li&gt;Consumer electronics and outdoor equipment&lt;/li&gt;&#10;&lt;li&gt;Industrial robotics, motors, control systems and heavy machinery&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Dust concentration adjustable 1–20 g/m³, ±0.5 g/m³ precision.&lt;/li&gt;&#10;&lt;li&gt;Airflow velocity 1–20 m/s, variable for static or dynamic testing.&lt;/li&gt;&#10;&lt;li&gt;Volume 0.6 m³ standard, up to 2.5 m³ custom, with reinforced acrylic observation windows.&lt;/li&gt;&#10;&lt;li&gt;Programmable test cycles 1–999 hours, with IP5X/IP6X compliance modes.&lt;/li&gt;&#10;&lt;li&gt;Turntable rotation speed adjustable from 2 to 10 r/min.&lt;/li&gt;&#10;&lt;li&gt;Dust blowing airflow velocity 1.5–8.9 m/s, or 18–29 m/s for higher-severity configurations.&lt;/li&gt;&#10;&lt;li&gt;Water-cooled cooling method on the higher-capacity models.&lt;/li&gt;&#10;&lt;li&gt;Cyclonic dispersion system for uniform particle distribution.&lt;/li&gt;&#10;&lt;li&gt;Hard-coated aluminium interior, wear-resistant seals and self-cleaning filter traps.&lt;/li&gt;&#10;&lt;li&gt;Real-time particle counter with temperature logging.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range"&gt;Model range&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SDB60&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SDB100&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SDB340&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SDJ60&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;SDJ250&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal capacity (m³)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.6&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;3.4&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2.5&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal dimension W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;800×800×1000&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×1000&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1500×1500×1500&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×1000&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1500×1500×1500&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;External dimension W×H×D (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1300×1500×2100&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1800×1400×2000&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2000×2300×2500&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;6000×8500×3350&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;6250×8500×3650&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Standards compliance&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;GB (G)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;GB (G)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;GB (G)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;GJB150 (J)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;GJB150 (J)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;RT+5 °C to +60 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;RT+5 °C to +60 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;RT+5 °C to +60 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;+20 °C to +80 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;+20 °C to +80 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Cooling method&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;—&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;—&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;—&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;water-cooled&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;water-cooled&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;Note: model suffix G denotes Chinese national standard GB, suffix J denotes national military standard GJB150. Chamber dimensions and special functions are customisable on request.&lt;/p&gt;</description></item><item><title>Semiconductor High Temperature Oven — EUT91 / EUT216 / EUT512 / EUT1000</title><link>https://www.testeqglobal.com/projects/semiconductor-oven/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/semiconductor-oven/</guid><description>&lt;p&gt;The TestEQ EUT-series high temperature oven is an electrically heated, air-circulation chamber for wafer baking and dehydration, component drying, polymer and photoresist curing, and package baking. It is used in semiconductor manufacturing, electronics production and materials processing where stable temperature control and repeatable thermal cycles matter.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Wafer baking and wafer dehydration&lt;/li&gt;&#10;&lt;li&gt;Photoresist and polymer thermal processing&lt;/li&gt;&#10;&lt;li&gt;Semiconductor packaging: die attach curing, epoxy curing, underfill curing&lt;/li&gt;&#10;&lt;li&gt;IC package baking and post-molding thermal treatment&lt;/li&gt;&#10;&lt;li&gt;Semiconductor component drying and moisture removal&lt;/li&gt;&#10;&lt;li&gt;Electronics component baking and ageing&lt;/li&gt;&#10;&lt;li&gt;Clean thermal processing and process development (R&amp;amp;D)&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Temperature range RT to 200 °C standard; 300–500 °C available as an option.&lt;/li&gt;&#10;&lt;li&gt;Temperature fluctuation ≤ ±0.5 °C and temperature deviation ≤ ±2.0 °C.&lt;/li&gt;&#10;&lt;li&gt;Heating time from RT to 200 °C approximately 35 minutes.&lt;/li&gt;&#10;&lt;li&gt;Contactless equal-period pulse width modulation heating control using SSR (Solid State Relay).&lt;/li&gt;&#10;&lt;li&gt;K-type armored thermocouple for temperature measurement.&lt;/li&gt;&#10;&lt;li&gt;Air circulation for even heat distribution across the working volume.&lt;/li&gt;&#10;&lt;li&gt;Stainless steel chamber construction with multi-layer shelves.&lt;/li&gt;&#10;&lt;li&gt;PLC or touchscreen controller; data logging, remote monitoring and MES integration available as options.&lt;/li&gt;&#10;&lt;li&gt;Safety features: leakage circuit breaker, fan overheat protection, over-temperature protection, thermal fuse, air duct extreme over-temperature protection.&lt;/li&gt;&#10;&lt;li&gt;Observation glass window fitted on RT–200 °C models; the 200 °C–500 °C configuration is supplied without an observation glass window.&lt;/li&gt;&#10;&lt;li&gt;Optional configurations include Nitrogen Inert Oven, Vacuum Oven, Class 100 Clean Oven, Multi-Chamber Oven, Automatic Loading System, Data Logging System and MES Communication Interface.&lt;/li&gt;&#10;&lt;li&gt;Custom chamber dimensions, wafer carriers, shelves and fixtures on request.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range"&gt;Model range&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EUT91&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EUT216&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EUT512&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EUT1000&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity (m³)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.091&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.216&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.512&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Internal dimension WxHxD (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;450x450x450&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;600x600x600&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;800x800x800&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000x1000x1000&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;External dimension WxHxD (mm)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1040x820x635&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1190x970x785&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1500x1210x1065&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1730x1480x1275&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Model series&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;High Temperature Oven, EUT&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;RT–200 °C (300–500 °C is optional)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature fluctuation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.5 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature rising speed rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;RT–200 °C, approx. 35 mins&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Heating control method&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Contactless equal-period pulse width modulation, SSR (Solid State Relay)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature measurement&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;K-type armored thermocouple&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Safety features&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Leakage circuit breaker, fan overheat protection, over-temperature protection, thermal fuse, air duct extreme over-temperature protection&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Observation glass window&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;RT–200 °C: with observation glass window. 200 °C–500 °C: without observation glass window&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;AC220V, 1 phase 3 lines, 50/60Hz; AC380V, 3 phase 5 lines, 50/60Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h2 id="standards"&gt;Standards&lt;/h2&gt;&#10;&lt;p&gt;The oven can be configured for thermal processing associated with semiconductor manufacturing, packaging and reliability qualification. Applicable standards depend on the specific process, product and customer qualification requirements:&lt;/p&gt;</description></item><item><title>Standard Climatic Test Chamber</title><link>https://www.testeqglobal.com/projects/environmental-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/environmental-chamber/</guid><description>&lt;p&gt;The TestEQ standard climatic test chamber reproduces controlled temperature and humidity conditions for reliability validation, qualification testing and environmental conditioning. It is the general-purpose platform in the TestEQ range, available in cabinet sizes and, on request, in larger configurations.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Electronics, PCB assemblies and semiconductor components&lt;/li&gt;&#10;&lt;li&gt;Automotive electrical and electronic equipment&lt;/li&gt;&#10;&lt;li&gt;Aerospace, defense and communication equipment&lt;/li&gt;&#10;&lt;li&gt;Materials, coatings, pharmaceuticals and packaging conditioning&lt;/li&gt;&#10;&lt;li&gt;Research and third-party testing laboratories&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Capacity 245 L to 1000 L in standard cabinet models.&lt;/li&gt;&#10;&lt;li&gt;Temperature range -70 °C to +180 °C.&lt;/li&gt;&#10;&lt;li&gt;Humidity range 5 % to 98 % RH; dew point range 7 °C to 87 °C with extended dew point conditions to -10 °C.&lt;/li&gt;&#10;&lt;li&gt;Temperature fluctuation ≤ ±0.5 °C; temperature deviation ≤ ±2.0 °C; temperature uniformity ≤ 2.0 °C.&lt;/li&gt;&#10;&lt;li&gt;Humidity uniformity ±1.0 % RH; constant-temperature control to ≤ ±0.3 °C for stable test conditions.&lt;/li&gt;&#10;&lt;li&gt;High-humidity capability such as 85 °C / 85 % RH for at least 1000 hours is available as an option, along with conditions such as 40 °C / 75 % RH, 55 °C / 10 % RH and 65 °C / 95 % RH.&lt;/li&gt;&#10;&lt;li&gt;Cold-hot balance control regulates heating and cooling output together. According to TestEQ test data the strategy can improve energy efficiency by up to 49 %.&lt;/li&gt;&#10;&lt;li&gt;Monitoring system with real-time data tracking, remote monitoring and fault diagnosis. Up to 16 chambers can be networked and controlled from mobile devices.&lt;/li&gt;&#10;&lt;li&gt;Noise level ≤ 68 dB.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;245–1000 L (cabinet); larger sizes on request&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-70 °C to +180 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature fluctuation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.5 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;5 % to 98 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±1.0 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Constant-temperature control&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.3 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Dew point range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;7 °C to 87 °C (extended to -10 °C)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Noise&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 68 dB&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h2 id="standards"&gt;Standards&lt;/h2&gt;&#10;&lt;p&gt;Chambers can be configured for test programs based on IEC 60068, MIL-STD-810H, ISO 16750 and JESD22, as well as customer-specific specifications.&lt;/p&gt;</description></item><item><title>Temperature Humidity Vibration Test Chamber — EVT / EVTH Series</title><link>https://www.testeqglobal.com/projects/temperature-humidity-vibration-test-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/temperature-humidity-vibration-test-chamber/</guid><description>&lt;p&gt;The TestEQ temperature humidity vibration test chamber is a combined environmental reliability system that applies controlled temperature, humidity and mechanical vibration to a product in one coordinated test environment. The configuration is associated with AGREE environmental testing, in which climatic conditions and mechanical vibration are evaluated together rather than as isolated factors.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Aerospace and defense equipment&lt;/li&gt;&#10;&lt;li&gt;Automotive and EV components&lt;/li&gt;&#10;&lt;li&gt;Electronics and communication equipment&lt;/li&gt;&#10;&lt;li&gt;Products requiring multi-stress environmental qualification&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Temperature range -70 °C to +180 °C (200 °C optional).&lt;/li&gt;&#10;&lt;li&gt;Humidity range 10 % to 98 % RH.&lt;/li&gt;&#10;&lt;li&gt;Temperature and humidity are controlled inside the chamber while a vibration system applies the required dynamic excitation.&lt;/li&gt;&#10;&lt;li&gt;Three-axis (3-Axis) AGREE configuration.&lt;/li&gt;&#10;&lt;li&gt;Combined temperature, humidity and vibration testing with a single coordinated profile.&lt;/li&gt;&#10;&lt;li&gt;When humidity is present while vibration is applied, mechanical movement can interact with moisture-related degradation mechanisms; the profile is defined accordingly.&lt;/li&gt;&#10;&lt;li&gt;PID control with programmable profile and RS-485 communication.&lt;/li&gt;&#10;&lt;li&gt;Actual specifications depend on chamber size, shaker selection, specimen characteristics and environmental requirements.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range-evth-series"&gt;Model range (EVTH series)&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Capacity&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Model variants&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Internal dimension W×H×D&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;External dimension W×H×D&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Vibration shaker table&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.408 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;EVTH408-40W5 / -55W5, EVTH408-40W10 / -55W10, EVTH408-40W15 / -55W15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;700×800×730 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;900×1790×2640 mm; 900×1900×2813 mm; 900×1900×2813 mm; 1000×2150×2640 mm; 1000×1900×2890 mm; 900×1900×2890 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;600×600 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.602 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;EVTH600-40W5 / -55W5, EVTH600-40W10 / -55W10, EVTH600-40W15 / -55W15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;800×940×800 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;900×1900×2813 mm; 1000×2150×2640 mm; 1000×1900×2890 mm; 900×1900×2890 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;800×800 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;EVTH1000-40W5 / -55W5, EVTH1000-40W10 / -55W10, EVTH1000-40W15 / -55W15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000×1000 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1200×1900×3200 mm; 1200×1900×3470 mm; 1200×1900×3470 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;800×800 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2.4 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;EVTH2350-40W5 / -55W5, EVTH2350-40W10 / -55W10, EVTH2350-40W15 / -55W15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1400×1200×1400 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1600×2100×3720 mm; 1600×2100×3950 mm; 1600×2100×3950 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1000×1000 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="temperature-ramp-rates-by-variant"&gt;Temperature ramp rates by variant&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Variant&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Temperature rising&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Falling speed rate&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;W5&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;7 °C/min average&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;6 °C/min average&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;W10&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;15 °C/min average&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;11 °C/min average&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;W15&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;15 °C/min average&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;15 °C/min average&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="rated-output-power-by-model"&gt;Rated output power by model&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Capacity&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;W5 (40W / 55W)&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;W10 (40W / 55W)&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;W15 (40W / 55W)&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.408 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;12 kW / 14 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;18 kW / 22 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;22 kW / 28 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.602 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;16 kW / 20 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;24 kW / 30 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;34 kW / 38 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;20 kW / 24 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;26 kW / 32 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;45 kW / 48 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2.4 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;35 kW / 44 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;54 kW / 65 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;65 kW / 85 kW&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-70 °C to +180 °C (200 °C optional)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature fluctuation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±0.5 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ ±2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 2.0 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;10 % to 98 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Humidity uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±1.0 % RH&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Relative humidity deviation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ +2.0 % to -3 % RH (humidity &amp;gt; 75 % RH); ≤ ±5.0 % RH (humidity ≤ 75 % RH)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Viewing window size&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;W330 × H360 mm (0.408 / 0.602 m³); W380 × H520 mm (1.0 / 2.4 m³)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Cooling system&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Wind cooling or water cooling / single-stage compressor (-40 °C); double-stage compressor (-70 °C)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Structural style&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;L - elevator, G - gantry elevator, F - fixture type&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Optional accessories&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Inner door with operation hole, recorder, water purifier, dehumidifier&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;AC 380 V, 3-phase, 5-line, 50/60 Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;Model designations include the EVT series. Performance examples are specified against IEC 60068-3-5.&lt;/p&gt;</description></item><item><title>Thermal Shock Test Chamber — ETS Series</title><link>https://www.testeqglobal.com/projects/thermal-shock-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/thermal-shock-chamber/</guid><description>&lt;p&gt;The TestEQ ETS-series thermal shock test chamber exposes a specimen to abrupt transitions between hot and cold zones to evaluate thermal shock resistance. A two-zone or three-zone layout is selected according to whether the specimen can be moved during the test.&lt;/p&gt;&#10;&lt;p&gt;&lt;img src="https://www.testeqglobal.com/images/projects/thermal-shock-chamber-1.jpg" alt="Thermal shock test chamber"&gt;&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Semiconductors, ICs and electronic components&lt;/li&gt;&#10;&lt;li&gt;PCB assemblies and solder joints&lt;/li&gt;&#10;&lt;li&gt;Automotive electronics and EV power components&lt;/li&gt;&#10;&lt;li&gt;Aerospace, defense and communication equipment&lt;/li&gt;&#10;&lt;li&gt;New materials, glass, ceramics and composites&lt;/li&gt;&#10;&lt;li&gt;Batteries and power modules&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="two-zone-and-three-zone-designs"&gt;Two-zone and three-zone designs&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Two-zone system: the specimen basket moves vertically or horizontally between a pre-heated zone and a pre-cooled zone. Basket transfer time is ≤ 10 seconds, and temperature recovery is within specification typically in ≤ 5 minutes.&lt;/li&gt;&#10;&lt;li&gt;Three-zone system: hot, cold and ambient zones are separate; the specimen can be kept stationary while air is switched between zones. Transition time is ≤ 3–10 seconds and mechanical stress from basket movement is eliminated.&lt;/li&gt;&#10;&lt;li&gt;The three-zone layout favours precision electronic assemblies, semiconductor devices and aerospace components where repeatability and data consistency are important.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;p&gt;&lt;img src="https://www.testeqglobal.com/images/projects/thermal-shock-chamber-3.jpg" alt="Basket transfer between hot and cold zones"&gt;&lt;/p&gt;</description></item><item><title>Thermal Vacuum Chamber</title><link>https://www.testeqglobal.com/projects/thermal-vacuum-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/thermal-vacuum-chamber/</guid><description>&lt;p&gt;The TestEQ thermal vacuum chamber reproduces the combined low-pressure and thermal conditions faced by equipment operating in space, for space simulation and for thermal cycling under vacuum. It provides high-vacuum performance together with an ultra-wide thermal range, allowing vacuum and thermal cycling to be applied at the same time.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Spacecraft, satellite and space equipment testing&lt;/li&gt;&#10;&lt;li&gt;Aerospace components and instruments&lt;/li&gt;&#10;&lt;li&gt;Semiconductor equipment and precision components&lt;/li&gt;&#10;&lt;li&gt;Outgassing and material evaluation under vacuum&lt;/li&gt;&#10;&lt;li&gt;Components requiring combined vacuum and thermal cycling&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;High vacuum level to 1.0×10⁻⁷ mbar.&lt;/li&gt;&#10;&lt;li&gt;No-load vacuum level 5×10⁻⁷ mbar at room temperature.&lt;/li&gt;&#10;&lt;li&gt;Temperature range -190 °C (liquid nitrogen cooling) to +200 °C.&lt;/li&gt;&#10;&lt;li&gt;Simultaneous vacuum and thermal cycling capability.&lt;/li&gt;&#10;&lt;li&gt;Stable pressure regulation across multiple vacuum levels.&lt;/li&gt;&#10;&lt;li&gt;Chamber, shroud and cooling system configured around the test item and required temperature profile.&lt;/li&gt;&#10;&lt;li&gt;Patent number CN202510795397.6.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;h3 id="model-range"&gt;Model range&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EZKT 1000-5&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EZKT 1200-5&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;EZKT 1700-5&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.402 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.785 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;2.65 m³&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Thermal shroud internal dimension (straight cylindrical section)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ø 800×800 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ø 1000×1000 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ø 1500×1500 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vacuum chamber internal dimension (straight cylindrical section)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ø 1000×1000 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ø 1200×1200 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ø 1700×1700 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Thermal plate dimension&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;600×500 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;800×700 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1300×1200 mm&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="common-specifications"&gt;Common specifications&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Capacity range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;0.5 m³ to 2.65 m³ (customizable)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;High vacuum level&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;1.0×10⁻⁷ Torr (1.33×10⁻⁷ mbar)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;No-load vacuum level&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;5.0×10⁻⁷ mbar (room temperature)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Pressure regulation in multiple ranges&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;stable operation at 1.0×10⁻², 1.0×10⁻³, 1.0×10⁻⁴, 1.0×10⁻⁵ and 1.0×10⁻⁶ mbar/Torr (room temperature)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vacuum cube leak rate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ 1×10⁻⁹ std/cc/sec&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Refrigeration modes&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;A: thermal sink + cold plate; B: thermal sink + heating cage; C: liquid nitrogen thermal sink + heating cage&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;gaseous nitrogen control -180 °C to +200 °C; mechanical refrigeration -80 °C to +150 °C; flooded liquid nitrogen -190 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature uniformity&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±2 °C (measured at any point on the heat sink and cold plate under stable conditions in a vacuum environment)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Rising / falling rate (mechanical cooling)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-70 °C to +100 °C ≥ 3 °C/min; +100 °C to -50 °C ≥ 3 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Rising / falling rate (optional, pressurised GN₂ recirculation)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;-150 °C to +125 °C ≥ 3 °C/min; +125 °C to -150 °C ≥ 3 °C/min&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vacuum acquisition system&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;mechanical pump / roots pump / molecular pump / cryopump&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Power&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;AC 380 V, 3-phase, 5-line, 50/60 Hz&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Patent&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;CN202510795397.6&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;h3 id="system-configuration-options"&gt;System configuration options&lt;/h3&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;System component&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Standard configuration&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Custom configuration&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vacuum vessel&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Chamber volume&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vacuum pumping system&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Thermal shroud&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Cold plate&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Optional&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Heating system&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Cooling system&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Payload fixture&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Optional&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Electrical feedthrough&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Optional&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Residual gas analyzer (RGA)&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Optional&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Data acquisition system&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Optional&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Thermal balance&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Optional&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Solar simulation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Optional&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Automated control&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;✓&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;Vacuum levels in the 10⁻⁵ to 10⁻⁷ Torr/mbar range are commonly associated with spacecraft TVAC qualification depending on mission requirements.&lt;/p&gt;</description></item><item><title>Thermal Vacuum Cleaning System</title><link>https://www.testeqglobal.com/projects/thermal-vacuum-cleaning-system/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/thermal-vacuum-cleaning-system/</guid><description>&lt;p&gt;The TestEQ thermal vacuum cleaning system combines controlled heating, vacuum extraction and optional inert-gas purging to remove residual moisture, volatile compounds and hydrocarbons from semiconductor manufacturing equipment parts. It is built for semiconductor fabs, equipment manufacturers, component refurbishment facilities and high-purity manufacturing environments that need repeatable thermal processing and contamination control.&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Semiconductor equipment parts drying and preparation&lt;/li&gt;&#10;&lt;li&gt;Vacuum bake-out of precision components&lt;/li&gt;&#10;&lt;li&gt;Moisture removal and removal of volatile organic residues&lt;/li&gt;&#10;&lt;li&gt;Outgassing reduction for vacuum-compatible assemblies&lt;/li&gt;&#10;&lt;li&gt;Cleaning and preparation of process chamber components&lt;/li&gt;&#10;&lt;li&gt;Drying after aqueous or solvent-based cleaning&lt;/li&gt;&#10;&lt;li&gt;Pre-conditioning of components before installation&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Chamber evacuated by a vacuum system selected for the required pressure range, chamber volume and process load.&lt;/li&gt;&#10;&lt;li&gt;Controlled heating according to a defined temperature recipe, with programmable thermal profiles.&lt;/li&gt;&#10;&lt;li&gt;Vacuum bake-out stage that continuously extracts released contaminants.&lt;/li&gt;&#10;&lt;li&gt;Optional nitrogen or compatible inert-gas purge for pressure cycling, cooling or removal of residual volatiles.&lt;/li&gt;&#10;&lt;li&gt;Controlled cooling and venting sequence before the chamber returns to atmospheric pressure.&lt;/li&gt;&#10;&lt;li&gt;Low-outgassing SUS304 / SUS316L chamber construction and component-specific fixtures.&lt;/li&gt;&#10;&lt;li&gt;PLC + touchscreen HMI control with recipe management, data logging, alarms and interlocks.&lt;/li&gt;&#10;&lt;li&gt;Fully automatic or semi-automatic operation.&lt;/li&gt;&#10;&lt;li&gt;Patent number CN202510795397.6.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="specifications"&gt;Specifications&lt;/h2&gt;&#10;&lt;table&gt;&#10;&#9;&lt;thead&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Parameter&lt;/th&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;th&gt;Value&lt;/th&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/thead&gt;&#10;&#9;&lt;tbody&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Vacuum level&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;≤ -0.1 MPa (customisable)&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature range&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;ambient to 450 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Temperature control accuracy&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;±1 °C&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Chamber material&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;SUS304 / SUS316L low-outgassing stainless steel&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Heating mode&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;radiant / conduction hybrid heating&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Cleaning mode&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;thermal + vacuum + optional gas assist&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Cycle time&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;30–120 minutes&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Control system&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;PLC + touchscreen HMI&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&#9;&#9;&lt;tr&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;Automation&lt;/td&gt;&#10;&#9;&#9;&#9;&#9;&#9;&lt;td&gt;fully automatic / semi-automatic&lt;/td&gt;&#10;&#9;&#9;&#9;&lt;/tr&gt;&#10;&#9;&lt;/tbody&gt;&#10;&lt;/table&gt;&#10;&lt;p&gt;Actual temperature range, ultimate vacuum, pumping speed, heating rate, thermal uniformity and cycle time are confirmed against the customer&amp;rsquo;s component, contamination level and required process specification. Chamber dimensions, temperature range, vacuum architecture, fixtures, gas purging and data logging can be customised.&lt;/p&gt;</description></item><item><title>Walk-in Environmental Chamber — EWTH Series</title><link>https://www.testeqglobal.com/projects/walk-in-environmental-chamber/</link><pubDate>Mon, 01 Jan 0001 00:00:00 +0000</pubDate><guid>https://www.testeqglobal.com/projects/walk-in-environmental-chamber/</guid><description>&lt;p&gt;The TestEQ EWTH-series walk-in environmental chamber provides a large test volume for bulky or heavy products and system-level test items. TestEQ builds walk-in rooms in modular-panel and fully welded constructions: because polyurethane panel insulation is limited to a maximum of 85 °C, a fully welded structure is used where a higher temperature range, faster temperature change rate or high-temperature high-humidity conditions are required.&lt;/p&gt;&#10;&lt;p&gt;&lt;img src="https://www.testeqglobal.com/images/projects/walk-in-environmental-chamber-1.jpg" alt="Walk-in environmental chamber"&gt;&lt;/p&gt;&#10;&lt;h2 id="applications"&gt;Applications&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Telecommunications, defense and aerospace equipment&lt;/li&gt;&#10;&lt;li&gt;Pharmaceutical, automotive and electronics industries&lt;/li&gt;&#10;&lt;li&gt;EV battery packs and energy storage systems&lt;/li&gt;&#10;&lt;li&gt;Large assemblies and system-level products&lt;/li&gt;&#10;&lt;li&gt;Products that must be driven or operated while under test&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;h2 id="configuration-and-features"&gt;Configuration and features&lt;/h2&gt;&#10;&lt;ul&gt;&#10;&lt;li&gt;Type A volumes from 7.8 m³ to 44.1 m³; Type B volumes from 6.8 m³ to 38.6 m³.&lt;/li&gt;&#10;&lt;li&gt;Low-temperature grades A to F: A = +25 °C, B = 0 °C, C = -20 °C, D = -40 °C, E = -60 °C, F = -70 °C. High temperature 85 °C (350 °C optional).&lt;/li&gt;&#10;&lt;li&gt;Humidity range 20 % to 98 % RH (5 % to 98 % RH is a special optional condition requiring a dehumidifier).&lt;/li&gt;&#10;&lt;li&gt;Temperature uniformity ≤ ±2.0 °C; temperature fluctuation ≤ ±0.3 °C.&lt;/li&gt;&#10;&lt;li&gt;Humidity fluctuation ±3 %RH; humidity deviation ≤ ±3 %RH (&amp;gt;75 %RH) and ≤ +5 %RH (≤75 %RH) at no load, constant state.&lt;/li&gt;&#10;&lt;li&gt;Modular structure for custom room sizes; internal and external dimensions are customised.&lt;/li&gt;&#10;&lt;li&gt;Chamber integrates refrigeration, heating, humidity generation, air circulation and PLC / AI control.&lt;/li&gt;&#10;&lt;li&gt;Rooms can be engineered to a customer&amp;rsquo;s own requirements, including airtight doors, safety locks, observation windows, interior lighting, access doors, personnel access and load handling.&lt;/li&gt;&#10;&lt;li&gt;Power AC380V, 3 phase 5 lines, 50/60 Hz.&lt;/li&gt;&#10;&lt;li&gt;Large walk-in temperature-humidity systems can be customised up to 4500 m³.&lt;/li&gt;&#10;&lt;/ul&gt;&#10;&lt;p&gt;&lt;img src="https://www.testeqglobal.com/images/projects/walk-in-environmental-chamber-3.jpg" alt="Walk-in chamber exterior"&gt;&lt;/p&gt;</description></item></channel></rss>