Rapid Temperature Change Chamber — EATH Series

The TestEQ EATH-series rapid temperature change chamber applies controlled linear temperature ramps to a product to accelerate thermal fatigue and reveal temperature-related failure mechanisms. It is intended for thermal cycling where transition rate, uniformity and repeatability are critical.

Rapid temperature change chamber

Applications

  • Semiconductor and IC reliability and thermal cycling
  • PCB assemblies, solder joints and interconnects
  • Automotive electronics and EV power modules
  • Aerospace and communication equipment
  • Battery cells and modules
  • Materials and coatings

Configuration and features

  • Temperature range -70 °C to +180 °C (200 °C optional).
  • Linear temperature ramp rates from 5 °C/min to 30 °C/min; common rates are 5, 10, 15, 20 and 25 °C/min, with up to 30 °C/min available for selected configurations.
  • Popular test range -40 °C to +85 °C.
  • Temperature fluctuation ≤ ±0.5 °C; temperature deviation ≤ ±2.0 °C; temperature uniformity ≤ 2.0 °C.
  • Temperature uniformity and control stability maintained at high ramp rates.
  • Air circulation is designed to keep temperature uniformity and the rate at which the specimen sees the programmed temperature consistent.
  • Air-cooled “Cold Fusion” airflow design.
  • Pump water supply; window W×H 380×520 mm.
  • PID control with programmable profile and RS-485 communication.
  • Options include a high ramp rate upgrade (≥ 30 °C/min).
  • Patent No.: CN201920954255.X.

Specifications

Model range (EATH series)

ModelsCapacity (m³)Interior W×H×D (mm)
EATH800-40W5 / EATH800-40W10 / EATH800-40W150.81000×1000×800
EATH800-55W5 / EATH800-55W10 / EATH800-55W150.81000×1000×800
EATH1000-40W5 / EATH1000-40W10 / EATH1000-40W151.01000×1000×1000
EATH1000-55W5 / EATH1000-55W10 / EATH1000-55W151.01000×1000×1000

The suffix after W indicates the configured ramp rate (W5 = 5 °C/min, W10 = 10 °C/min, W15 = 15 °C/min). Exterior dimensions vary with the accelerated-rate and temperature-range configuration; the source lists exterior W×H×D values of 1200×900×2670, 1200×930×2870, 1200×900×1970 and 1200×1900×2870 mm across the EATH800 / EATH1000 range.

Common specifications

ParameterValue
Temperature range-70 °C to +180 °C (200 °C optional)
Ramp rate (linear)5–30 °C/min
Common rates5 / 10 / 15 / 20 / 25 °C/min
Typical range-40 °C to +85 °C
Temperature fluctuation≤ ±0.5 °C
Temperature deviation≤ ±2.0 °C
Temperature uniformity≤ 2.0 °C
Airflow (Cold Fusion)200 L/Sec / 800 L/Sec (by configuration)
Window W×H (mm)380×520
Humidity range (%RH)10–98 %RH
Humidity uniformity±1.0 %RH
Relative humidity deviation≤ +2.0 to −3 %RH (>75 %RH); ≤ ±5.0 %RH (≤75 %RH)
Water supplypump supply
ControlPID, programmable profile, RS-485
Noise≤ 68 dB
PowerAC380V, 3 phase 5 lines, 50/60 Hz
Patent No.CN201920954255.X

The humidity indicator applies to humidity-configured chambers. Actual performance depends on chamber size, temperature range, specimen mass, fixture design and test conditions; ramp-rate performance should be evaluated under the intended test load.

Programmable temperature profile

Standards

Chambers can be configured for test programs based on IEC 60068-2-14, IEC 60068-3-5, JEDEC JESD22-A104, MIL-STD-810, AEC-Q100, ISO 16750 and RTCA DO-160.

To match a ramp rate to a test profile, contact us with the required range, rate and specimen. Related: Thermal Shock Test Chamber , Temperature Humidity Vibration Test Chamber .

Tell us the test standard and the specimen

Send the standard, the specimen size and heat load, the temperature or pressure range. Our engineers will come back with a chamber configuration.