Sand and Dust Test Chamber — SDB / SDJ Series

The TestEQ sand and dust test chamber reproduces airborne dust, sand particle and dry-climate conditions inside a controlled cabinet. It is used to verify enclosure protection against dust ingress and particle contamination in desert, construction, military and industrial environments, following IEC 60529 IP5X/IP6X, MIL-STD-810H Method 510.7 and ISO 20653.

Applications

  • Automotive components, sensors, ECUs and charging systems
  • EV battery components and enclosures
  • Aerospace, avionics and outdoor communication equipment
  • Consumer electronics and outdoor equipment
  • Industrial robotics, motors, control systems and heavy machinery

Configuration and features

  • Dust concentration adjustable 1–20 g/m³, ±0.5 g/m³ precision.
  • Airflow velocity 1–20 m/s, variable for static or dynamic testing.
  • Volume 0.6 m³ standard, up to 2.5 m³ custom, with reinforced acrylic observation windows.
  • Programmable test cycles 1–999 hours, with IP5X/IP6X compliance modes.
  • Turntable rotation speed adjustable from 2 to 10 r/min.
  • Dust blowing airflow velocity 1.5–8.9 m/s, or 18–29 m/s for higher-severity configurations.
  • Water-cooled cooling method on the higher-capacity models.
  • Cyclonic dispersion system for uniform particle distribution.
  • Hard-coated aluminium interior, wear-resistant seals and self-cleaning filter traps.
  • Real-time particle counter with temperature logging.

Specifications

Model range

ParameterSDB60SDB100SDB340SDJ60SDJ250
Internal capacity (m³)0.61.03.41.02.5
Internal dimension W×H×D (mm)800×800×10001000×1000×10001500×1500×15001000×1000×10001500×1500×1500
External dimension W×H×D (mm)1300×1500×21001800×1400×20002000×2300×25006000×8500×33506250×8500×3650
Standards complianceGB (G)GB (G)GB (G)GJB150 (J)GJB150 (J)
Temperature rangeRT+5 °C to +60 °CRT+5 °C to +60 °CRT+5 °C to +60 °C+20 °C to +80 °C+20 °C to +80 °C
Cooling method———water-cooledwater-cooled

Note: model suffix G denotes Chinese national standard GB, suffix J denotes national military standard GJB150. Chamber dimensions and special functions are customisable on request.

Common specifications

ParameterValue
Dust concentrationadjustable 1–20 g/m³ (±0.5 g/m³)
Airflow velocity1–20 m/s
Volume0.6 m³ standard to 2.5 m³ custom
Test durationprogrammable 1–999 hours
Compliance modesIP5X / IP6X
PowerAC 220 V, 1 phase 3 lines, 50/60 Hz; AC 380 V, 3 phase 5 lines, 50/60 Hz

Standards

Chambers are designed for IEC 60529 IP5X/IP6X, MIL-STD-810H Method 510.7, ISO 20653, and the Chinese national standard GB and military standard GJB150.

IP5X permits limited dust penetration; IP6X requires complete dust protection. To match a chamber size, dust concentration and airflow profile to a product and test standard, contact us with the specimen and required conditions. Related: Temperature Humidity Test Chamber , Altitude (Low-pressure) Test Chamber , Thermal Shock Test Chamber , Custom Non-standard Test Chamber .

Tell us the test standard and the specimen