Thermal Shock Test Chamber — ETS Series

The TestEQ ETS-series thermal shock test chamber exposes a specimen to abrupt transitions between hot and cold zones to evaluate thermal shock resistance. A two-zone or three-zone layout is selected according to whether the specimen can be moved during the test.

Thermal shock test chamber

Applications

  • Semiconductors, ICs and electronic components
  • PCB assemblies and solder joints
  • Automotive electronics and EV power components
  • Aerospace, defense and communication equipment
  • New materials, glass, ceramics and composites
  • Batteries and power modules

Two-zone and three-zone designs

  • Two-zone system: the specimen basket moves vertically or horizontally between a pre-heated zone and a pre-cooled zone. Basket transfer time is ≤ 10 seconds, and temperature recovery is within specification typically in ≤ 5 minutes.
  • Three-zone system: hot, cold and ambient zones are separate; the specimen can be kept stationary while air is switched between zones. Transition time is ≤ 3–10 seconds and mechanical stress from basket movement is eliminated.
  • The three-zone layout favours precision electronic assemblies, semiconductor devices and aerospace components where repeatability and data consistency are important.

Basket transfer between hot and cold zones

Configuration and features

  • Temperature range -70 °C to +200 °C.
  • Preheating range +60 °C to +200 °C; heating rate +60 °C to +200 °C ≤ 20 min.
  • Cooling rate from +20 °C to -70 °C ≤ 30 min.
  • Fast temperature transition and controlled recovery support repeated thermal shock cycling (>2000 cycles of continuous testing on supported configurations).
  • PID control with touchscreen programming and RS-485 communication.
  • Options include the number of basket positions, load capacity and test fixtures, selected against the specimen and load profile.

Specifications

Model range

Two-zone vertical basket chambers (ETS12 / ETS15)

ParameterETS12-20A-LETS15-4.5A-L
Capacity2.1 L4.5 L
Internal dimension W×H×D120×150×120 mm150×150×200 mm
External dimension W×H×D1140×1785×1240 mm1200×1785×1320 mm
Basket capacity (uniform load)1.0 kg2.0 kg
Hot / cold zone internal dimension260×350×440 mm (40 L)290×350×520 mm (52 L)
High temperature+150 °C (200 °C optional)+150 °C (200 °C optional)
Low temperature-65 °C-65 °C

Two-zone vertical basket chambers (ETS23 / ETS60 / ETS125)

ParameterETS23ETS60ETS125
Capacity0.023 m³0.06 m³0.125 m³
Internal dimension W×H×D270×310×270 mm380×370×430 mm470×410×650 mm
External dimension W×H×D700×1534×1800 mm875×1895×1970 mm970×1895×2350 mm
Model (-40W-D)ETS23-40W-DETS60-40W-DETS125-40W-D
Model (-55W-D)—ETS60-55W-DETS125-55W-D
Model (-65W-D)ETS23-65W-DETS60-65W-DETS125-65W-D
Rated power (-40W)13 kW16 kW20 kW
Rated power (-55W)—18 kW22 kW
Rated power (-65W)14 kW22 kW24 kW
Approx. weight520 kg960 kg1300 kg

Three-zone chambers (ETS70 / ETS110 / ETS200 / ETS300)

ParameterETS70ETS110ETS200ETS300
Capacity0.07 m³0.11 m³0.2 m³0.3 m³
Internal dimension W×H×D410×460×370 mm650×460×370 mm650×460×670 mm970×460×670 mm
External dimension W×H×D1470×1860×1570 mm1710×1860×1570 mm1710×1860×1870 mm2030×1860×1870 mm
Model (-40W)ETS70-40WETS110-40WETS200-40WETS300-40W
Model (-55W)——ETS200-55WETS300-55W
Model (-65W)ETS70-65WETS110-65W—ETS300-65W
Rated power (-40W)26 kW29 kW37 kW37 kW
Rated power (-55W)——38 kW38 kW
Rated power (-65W)38 kW42 kW—58 kW
Approx. weight1050 kg1150 kg1400 kg1470 kg

Two-zone horizontal basket chambers (ETS300 / ETS500 / ETS1000)

ParameterETS300ETS500ETS1000
Capacity0.30 m³0.50 m³1.00 m³
Internal dimension W×H×D800×620×600 mm1000×800×620 mm1200×1000×800 mm
External dimension W×H×D2150×1980×1700 mm2550×2140×1980 mm2950×2400×2250 mm
Model (-40W-D)ETS300-40W-DETS500-40W-DETS1000-40W-D
Model (-55W-D)—ETS500-55W-DETS1000-55W-D
Model (-65W-D)ETS300-65W-D——
Rated power (-40W)35 kW50 kW80 kW
Rated power (-55W)—55 kW85 kW
Rated power (-65W)48 kW——
Approx. weight1650 kg2250 kg3250 kg

Common specifications

ParameterValue
Testing-zone temperature range-40W(-D): +60 °C to +150 °C / 0 °C to -40 °C; -55W(-D): +60 °C to +150 °C / 0 °C to -55 °C; -65W(-D): +60 °C to +150 °C / 0 °C to -65 °C; optional -70W(-D): +60 °C to +200 °C / 0 °C to -70 °C
Transfer time (two-zone basket)≤ 10 s
Transition time (three-zone)≤ 3–10 s
Temperature stability±0.5 °C
Preheating range+60 °C to +200 °C; heating rate +60 °C to +200 °C ≤ 20 min
Precooling range-75 °C to 0 °C; cooling rate +20 °C to -70 °C ≤ 30 min (≤ 70 min for the three-zone configuration)
Heat-storing slotRT to 200 °C / about 15 min (two-zone); RT to 200 °C / about 30 min (three-zone)
Cool-storing slotRT to -70 °C / about 15 min (two-zone); RT to -70 °C / about 45 min (three-zone)
Recovery / conversion time≤ 0.5 to 3 min / ≤ 3 s (two-zone); ≤ 5 min / ≤ 5 s (three-zone)
Control precision / distribution accuracy±0.5 °C / ±2 °C
Temperature fluctuation / deviation / uniformity (three-zone)≤ ±0.5 °C / ≤ ±2.0 °C / ≤ 2.0 °C
Cooling systemSemi-hermetic double-stage compressor (water-cooled type); hermetic double-stage compressor (air-cooled type)
Control systemPLC + touch screen
Cycle life> 2000 cycles of continuous testing
PowerAC 380 V, 3-phase, 5-line, 50/60 Hz
OptionsLN₂ cooling to -196 °C, viewing window, large-volume custom chambers (up to 12,000 L, three-zone), remote monitoring (Modbus / IoT), semiconductor test mode (JEDEC)

Model designations include the ETS series (for example ETS23-40W-D, ETS125-65W-D, ETS300-40W-D, ETS500-55W-D); the final specification depends on chamber model, transition requirement and test load.

Rapid temperature recovery

Standards

Chambers can be configured for test programs based on MIL-STD-810H Method 503.7, IEC 60068-2-14, JESD22-A104, MIL-STD-883, GJB150.5A-2009, GJB360B-2009, GB/T 2424.13-2002 temperature shock test, GB 2423.1-2008 / IEC 6008-2-1-2007 low-temperature test methods, GB 2423.2-2008 high-temperature test methods, GB/T 10589-2008 (technical conditions for low-temperature test chambers), GB/T 11158-2008 (technical conditions and specifications for high-temperature test chambers), and ISO 16750.

To select a two-zone or three-zone configuration, contact us with the specimen, required temperature range and transition requirement. Related: Rapid Temperature Change Chamber , High and Low Temperature (Humidity) Test Chamber .

Tell us the test standard and the specimen

Send the standard, the specimen size and heat load, the temperature or pressure range. Our engineers will come back with a chamber configuration.